Product Data - MERSORB® HT
mercury adsorbent for Hot Gas



PERMANENT MERCURY ADSORBENT
MERCURY VAPOR REMOVAL FROM HOT GASES


BENEFITS                 
• Longer Service Life
• High Hg Removal Efficiency    
• Low Initial AND End-of-Life ∆P
• Clean Operation
• Dependable Technical Support

PERFORMANCE FEATURES
• Pellets Minimize Flow Channeling, thus Maximizing Adsorbent Performance & Life
• 50% Lower Pressure Drop: 3mm pellets vs. 4x10 granular
• Hard, Low Dust Pellets
• Backed by Extensive Lab & Field Test Data

PROPERTIES, TYPICAL

 Steam-Activated, coal-based, pellet diameters

3mm & 4mm

 Surface Area, substrate, N2 BET method

1,000 m2/g

 CCl4 Activity (ASTM D3467)

60 wt. %

 Hardness (ASTM D3802)

97 to 99 %

 Apparent Density (ASTM D2854)

33 to 37 Lb/Ft3 (530 to 590 Kg/m3)

 Moisture Content (ASTM D2867)

3 wt. % max, as packaged

 Elemental Sulfur Content

10 to 16 wt. %

 Mercury Equilibrium Capacity in Gas Treatment  Applications

≥ 20 kg Hg/100 kg fresh adsorbent

 Recycling

Can be processed by Hg recycling companies Packaging: Type-Net Weight

 Packaging: Type-Net Weight

Fiber Drums - 170 Lb, Steel Drums - 220 Lb (100 kg)
Bulk Bags - 2,000 Lb; 1,000 Lb; 500 kg


APPLICATIONS
MERSORB® HT mercury adsorbent has demonstrated Hg removal to < 0.010 μg Hg/Nm3. Applications include removal of mercury from Hot Synthesis Gas, & removal of Hg from Incineration Off-Gas to meet pollution effluent permit levels. For treating gases at temperatures > 150 °F (65 °C), we recommend MERSORB® HT mercury adsorbent.

SERVICES AVAILABLE:
Adsorption Process Design Service, Field Technical Services. Manufactured in Columbus, OH, USA by NUCON International Inc. to ASME NQA-1 QA code. Product is shipped fully active: No Activation Required. No Nitrogen Blanket Required.



Providing Solutions to remove mercury for emission control, corrosion prevention and catalyst protection.



Selective Adsorption Associates, Inc. (SAA) offers over 40 years of experience in Process Engineering of Adsorption Systems for Gas and Liquid Drying, Sulfur Compound Removal, Emission Control, and over 20 years of Process Design experience in Mercury Removal Systems.

CAUTION: Wet activated carbon removes oxygen from air. Thus, an asphyxiation hazard exists inside enclosed spaces containing activated carbon. Use appropriate safety precautions when entering vessels or other enclosed spaces containing activated carbon. Exposure to strong acids and oxidizers can cause formation of toxic H2S gas.

MERSORB® is a trademark of Nucon International, Inc. (NUCON®) for impregnated activated carbons used to remove mercury from gases and liquids. NUSORB® is a trademark of NUCON for its activated carbons. Information presented herein is believed to be accurate and reliable but does not provide any guarantee or warrantee by NUCON® or by Selective Adsorption Associates, Inc. Nothing herein shall be construed as an invitation to use processes covered by patents without proper arrangements with individuals or companies owning those patents.

AntiMercure® is a Registered Trademark of Selective Adsorption Associates, Inc. (SAA) for its Process for removing mercury from water; AntiMercure™ is a trademark of SAA for its pre-Engineered Systems for removing mercury from water. All Rights Reserved.